P265GH

Data verified

P265GH is the EN 10028-2 workhorse pressure-vessel steel for European boiler and vessel fabrication — the normalized C-Mn grade that sits a step below P355GH in strength. Its GH suffix marks it as proven for high-temperature (elevated-temperature) service.

DIN1.0425 (P265GH)
AISIA516 Gr.70 (near)
JISSGV410 (near)
CategoryStructural & HSLA Steel

Chemical composition

ElementContent (%)
C≤0.20
Si≤0.40
Mn0.80–1.40
P≤0.025
S≤0.010
Cr≤0.30
Cu≤0.30
Mo≤0.08
Ni≤0.30

Weight percent, per the governing standard ranges. Actual values per heat are on the mill certificate.

Properties

Yield strength≥265 MPa
Tensile strength410–530 MPa
Density7.85 g/cm³
ServiceElevated-temperature pressure equipment (EN 10028-2)

Heat treatment

Supplied normalized. Rated for pressure service at elevated temperature under the Pressure Equipment Directive.

Equivalent grades

StandardDesignation
din1.0425 (P265GH)
aisiA516 Gr.70 (near)
jisSGV410 (near)
gbQ245R (near)

Compare side by side: P265GH vs P355GH · P265GH vs A516 Gr.70

Equivalents overlap in chemistry and use but are not always identical — see our equivalents guide before substituting in certified designs.

Applications & Processing

Applications: Boilers, steam generators, pressure vessels, heat exchangers, hot-water and process plant across the EU PED market.

Processing: Excellent weldability by all standard processes; the European default where A516 Gr.70 is the American default — certificates differ, service is equivalent.

FAQ

P265GH vs A516 Gr.70?
Near-equivalents for ambient/elevated-temperature vessels: P265GH is the EN grade (265 MPa yield), A516 Gr.70 the ASTM grade (260 MPa yield). Either is normally acceptable where the design code allows both.

Need P265GH from stock?

Steel.Wiki is sponsored by Shenzhen NewAsia Special Steel (Nasteel), a special-steel stockholder in Shenzhen stocking mold, tool and alloy steels with EN 10204 3.1 certification.

Ask for a quotationVisit Nasteel

Source: EN 10028-2 published ranges · Last updated 2026-11-03. Data is indicative — verify critical values against the governing standard and mill certificate before use.